Not sure how to select the right channel/river online flow meter? These four points will help you.


Release time:

2021-08-30

Channel/river flow measurement is a crucial component of water resources informationization. It is widely applied in areas such as irrigation water metering, water resource scheduling and allocation, hydrological data monitoring, and flood prevention and control.  

Regarding channel/river flow measurement, we have summarized four key points of interest: an overview of flow measurement, primary methods of flow measurement, mainstream sensors for online flow measurement, and how to select appropriate sensors in practical applications.

 1. What is flow?

In hydrology, river flow is defined as the volume of water passing through a given river cross-section per unit of time. The flow calculation is derived by multiplying the average flow velocity of the fluid within the carrier by the cross-sectional area of the carrier, with units such as m³/s or m³/h.

  

 

 Note: Typically, the flow velocity of each layer within the same cross-section and the flow velocity of each cross-section are different, so the average flow velocity must be used. (Due to viscosity, liquids exhibit two distinct flow patterns. When liquid particles move in an orderly manner without mixing, this is called laminar flow. When liquid particles move irregularly, mix with one another, and follow chaotic, curved trajectories, this is called turbulent flow, also known as turbulent flow.)

 ● Average flow velocity

Flow velocity refers to the displacement of fluid particles per unit time. The flow velocity at each point in a channel or river is different; the velocity near the river (channel) bank is slower, while the velocity at the river center near the water surface is the fastest. For simplicity of calculation, the average flow velocity across the cross-section is typically used to represent the flow velocity at that cross-section.

  

 

  2. Current methods for measuring channel/river flow: These are mainly divided into the structure method and the sensor flow measurement method.

  

 

 3. Currently, the mainstream sensors for online flow measurement can be roughly divided into four categories: 1) ultrasonic flow measurement, 2) electromagnetic flow measurement, 3) radar wave flow measurement, and 4) mechanical flow measurement.

 

  

 

  Below is an introduction to the various mainstream flow measurement sensors currently available. This is a lengthy article—are you ready?

 

  ◆ Time-of-flight flow meters—divided into pipeline-type and open-channel-type

 

Acoustic time-of-flight flow meters are based on the principle of flow measurement using the velocity-area method. When sound waves propagate in still water, they have a constant speed. This propagation speed may vary slightly with changes in water temperature, salinity, and sediment content, but when the flow conditions are constant, the propagation speed remains constant. When propagating with the flow, the actual propagation speed is the sum of the sound speed and the flow velocity; when propagating against the flow, the actual propagation speed is the difference between the sound speed and the flow velocity. Thus, between two fixed points upstream and downstream in a river, there is a time difference in the propagation of sound waves with and against the flow. By measuring this time difference, the flow velocity can be determined. This method of measuring flow velocity is referred to as the “time-of-flight method.”

  

  ◆ Ultrasonic Time-of-Flight Open Channel Flow Meter

 The acoustic time-of-flight flow measurement system consists of a set (or several sets) of acoustic transducers, a main unit, signal cables, and a power supply.

 The acoustic transducers receive instructions from the flow measurement controller to emit acoustic pulses and transmit the received acoustic pulse signals to the flow measurement controller. The flow controller collects the propagation time of the acoustic pulses in the water and water level data, calculates the average flow velocity of the water layer based on the propagation time difference, and combines this with the cross-sectional area and average flow velocity of the cross-section to determine the cross-sectional flow rate. The acoustic transducers may be equipped with water level sensors, which can simultaneously transmit the measured water level data to the main unit, or they can be connected to other compliant water level gauges.

  

 

  ◆ Ультразвуковой расходомер с методом измерения разности фаз

  

 

  

 

  ◆ Ultrasonic Doppler Flowmeter — primarily categorized into portable, fixed, and single-point types

 

Based on the acoustic Doppler effect, when there is relative motion between the sound source and the observer, the frequency perceived by the observer differs from the frequency emitted by the sound source. This frequency change caused by relative motion is directly proportional to the relative velocity between the two objects. The ultrasonic transmitter serves as a fixed sound source, while solid particles moving with the fluid act as the “observer” with relative motion to the sound source. Of course, it merely reflects the incident ultrasonic waves back to the receiver. The frequency difference between the emitted sound waves and the received sound waves is the Doppler frequency shift caused by the movement of solid particles in the fluid. Since this frequency difference is directly proportional to the fluid flow velocity, measuring the frequency difference can determine the flow velocity. From this, the fluid flow rate can be calculated.

  

 

  ◆ Towed

Acoustic Doppler current profiler

 Acoustic – Emits acoustic pulses at a fixed frequency.

 Doppler – Receives reflected acoustic signals with Doppler frequency shifts, and calculates the relative velocity in the beam direction based on the frequency shift.

 Current – Applies four wave velocities to calculate relative velocity, the angle between wave velocities, and attitude data (heading, pitch, roll).

 Profiler – Measures current velocity at different depth levels (depth cells)

 ADCP typically has three or more transducers, simultaneously emitting and receiving three or more acoustic signals, obtaining three or more relative velocities

 Signals are processed independently by beam and converted into relative velocity in the beam direction

 Using the angle between wave speeds, the relative velocity in the beam direction (beam coordinates) is converted into horizontal and vertical velocities (Earth coordinates)

  

 

  ◆ Fixed-type

 

The acoustic Doppler flowmeter is equipped with two transducers, which are installed at a certain angle to the center axis. Each transducer functions as both a transmitter and a receiver. The sound waves emitted by the transducers are concentrated within a narrow range, also known as the sound beam. Assuming that the movement speed of the suspended particles is the same as the water flow velocity, when the movement direction of the suspended particles is toward the transducer, the received echo frequency is higher than the transmitted wave frequency; when the movement direction of the suspended particles is away from the transducer, the received echo frequency is lower than the transmitted frequency. The acoustic Doppler frequency shift is the difference between the transmitted sound wave frequency and the echo frequency:

  

 

  ◆ 单点式

  传感器有两个换能器,一个发射,一个接收。当传感器正对着水流方向,也就是逆流测量的前提下:

  1、水流静止情况下,接收到的频率跟发射频率一样;

  2、流速越快,接收传感器接收到的频率越快,会高于发射的频率;

  3、流速越慢,接收传感器接收到的频率越慢,但是会高于发射的频率。

  安装使用时必须要将传感器正对着水流方向。

  

 

  ◆ Electromagnetic flowmeter—primarily divided into pipe-type (full-bore/non-full-bore) and open-channel types

 

Electromagnetic flowmeter: Based on Faraday's law of electromagnetic induction to measure flow rate U=B*L*v (U—induced electromotive force, B—magnetic field strength, L—conductor length, v—conductor velocity)

 

A coil wound with copper wire generates an alternating magnetic field B. A controlled current ensures that the magnetic field strength remains constant throughout the measurement process. The conductor length L (the distance between the two measuring electrodes within the measurement pipe's inner diameter) is a constant. The only variable in the equation is the fluid velocity v. The instrument directly measures the induced voltage between the electrodes, which is linearly proportional to the fluid velocity U~v. Thus, the velocity is calculated. Electromagnetic flow meters measure velocity rather than volume.

  

 

  ◆ Pipe-type

 Electromagnetic pipe flowmeter (full pipe)

 ● Accuracy class: It is recommended to select a flowmeter with a full-scale output error of less than ±1.5% to ±2.5%;

 ● Length of straight pipe sections before and after the flowmeter: The length of the straight pipe section before the flowmeter should be greater than 5 times the pipe diameter, and the length of the straight pipe section after the flowmeter should be greater than 2 times the pipe diameter. No gate valves should be installed within this range;

 ● Flow velocity and diameter: The selected instrument diameter may differ from the pipe diameter. The upper limit flow velocity should not exceed 5 m/s, and the lower limit flow velocity should not be less than 0.5 m/s;

 ● The transmitter should have a pressure-resistant sealing performance test report.

  

 

  ◆ Electromagnetic pipe flowmeter (non-full pipe)

 The electromagnetic non-full-bore flow meter is an automatic flow measurement instrument that uses the velocity-area method to continuously measure the flow rate of fluids in open pipelines (such as half-pipe sewage pipelines and high-flow pipelines without overflow weirs). It can measure and display instantaneous flow rate, velocity, cumulative flow rate, and other data. It is particularly suitable for metering applications in municipal rainwater, wastewater, sewage discharge, and irrigation water pipelines.

 The non-full pipe flow meter consists of an electromagnetic velocity sensor, an ultrasonic water level sensor, and a flow display unit, which continuously measure the fluid velocity and water level in the pipeline. Users only need to input the inner diameter of a circular pipe or the width of a square pipe, and the GLP-LSC type non-full pipe flow meter will automatically calculate the flow rate within the pipeline and display measurement parameters such as instantaneous flow rate, velocity, and cumulative flow rate.

  

 

  ◆ 明渠式

  电磁明渠流量计

  电磁明渠流量测量系统以流速-水位运算法为基础,并采用了先进的伺服水位跟踪测速系统和微处理器,从而确保测速和运算的准确性的一种新型智能化流量系统,根据渠道的宽度和测量精度的要求,采用明渠测流的数学模型。

  根据传感器实测的水位值、流速值和已置入的渠道几何尺寸、边坡系数、渠道精度、水力坡道、流速垂直平面修正系数,并按照预定的数学模型计算出渠道的断面平均瞬时流量。

  

 

  ◆ Radar Wave Flow Meter - Primarily divided into fixed-type and cable-type

 

When operating, it emits electromagnetic waves toward the water surface. When these waves encounter moving water, they scatter and form echoes. Since the received echo frequency shifts relative to the transmitted frequency, the water surface flow velocity can be calculated using the Doppler frequency equation. A moving target generates a low-frequency output signal at the radar sensor. The frequency of this signal depends on the movement speed, while the amplitude depends on the installation distance, reflectivity, and size of the moving target. The Doppler frequency F is directly proportional to the movement speed. The system of a fixed-point radar flowmeter can be connected to multiple radar probes, effectively setting up multiple measurement lines. By combining cross-sectional parameters, it calculates cross-sectional flow and performs fixed-point measurements.  

 

  ◆ Pole-mounted fixed-type

 Radar flowmeter

 Fully automatic radar flowmeter. It uses advanced planar microwave radar technology to measure the flow velocity and water level of water bodies in a non-contact manner. Based on the built-in software algorithms, it calculates and outputs real-time cross-sectional flow and cumulative flow, and can be used for flow measurement in scenarios such as rivers and irrigation channels.

 Based on the Doppler frequency shift effect in physics, when water flows, it creates relative motion with the flow meter, causing the radar wave signals emitted by the instrument to undergo frequency shifts. The frequency shift is directly proportional to the water flow velocity. By measuring the frequency shift to determine the water flow velocity, combined with pulse radar-measured water level and cross-sectional data to calculate the dynamic water cross-sectional area, the instantaneous flow rate is then calculated based on the measured flow velocity and water cross-sectional area.

  

 

  ◆ Cable-mounted

 Cable-mounted radar flowmeter

 The mobile radar wave online flow monitoring system adheres to the principles of unmanned operation, simplicity and practicality, ease of maintenance, and reliable accuracy. It uses radar waves to monitor vertical velocity in real time, simultaneously collects corresponding water levels, calculates flow using the partial area method, and achieves automatic flow monitoring. The flow measurement method complies with the “River Flow Measurement Standards” and the “Hydrological Cableway Measurement Standards,” and the data output conforms to the “Hydrological Data Compilation Standards,” seamlessly integrating with data compilation software.

 The radar cableway-type flow measurement system is a fully automatic flow measurement system that integrates flow measurement, wireless transmission, flow measurement, database management, website publication, and hydrological station business processing. Users can view station water levels, flow velocities, flow rates, and equipment status via the internet. Staff at the central hydrological station can remotely download station data from the municipal bureau's central database via the internet, analyze and process the data on computers, and generate various hydrological reports. This completely eliminates the traditional manual workflow from measurement to compilation in hydrology, upgrading the three core hydrological functions of “measurement, reporting, and compilation” with modern technological means.

 

 

 

 ◆ Mechanical flow meters (rotors) – primarily divided into cup-type and propeller-type

 Mechanical flow measurement operates based on the momentum transfer from the water flow to the velocity rotor. When water flows past the velocity rotor, the linear kinetic energy of the water flow generates torque on the rotor. This torque overcomes the rotor's inertia, bearing friction, and fluid resistance caused by the relative movement between the water flow and the rotor, thereby causing the flow meter rotor to rotate. Within a certain range of water flow velocities, the rotational speed of the flow meter rotor exhibits a relatively stable approximate linear relationship with the water flow velocity. By using specially designed equipment to measure the number of rotations of the rotor over a predetermined time period, and by consulting the corresponding calibration formula or calibration relationship curve for the flow meter, the water flow velocity can be obtained or calculated. Alternatively, by inputting relevant coefficients into a secondary instrument, the water flow velocity can be automatically calculated.

  

 

  ◆ Propeller-type

 

  Propeller-type flowmeter

 

  ● Propeller-type water meters can be used in channels with high silt content and gentle slopes (less than 1/10,000);

 

  ● Flow measurement range: The flow measurement range varies by product, with a minimum of 0.05–0.6 m³/s;

 

  ● The flow velocity in the culvert should be less than 2 m/s;

 

  ● The culvert should operate under submerged flow conditions;

 

  ● The flow measurement error should not exceed ±5%.

  

 

  ◆ Vortex flow meter

 Vortex flow meter

 ● A vortex flow meter is a river hydrological testing instrument used to measure the average flow velocity at predetermined measurement points across the cross-section of rivers, channels, reservoirs, lakes, pipelines, etc., thereby determining the flow rate of that cross-section.

 ● In irrigation channel water measurement, it is generally used to calibrate the water level-flow rate relationship curve.

  

 

  ◆ Rotor-type innovation application

 Rotor-type flowmeter application—track flow measurement vehicle

 The automated river cross-section flow measurement station is centered around an automated river cross-section flow measurement vehicle, equipped with a propeller-type flowmeter, lead fish, communication terminal, intelligent power supply system, security system, and video surveillance system, to achieve automatic collection and transmission of open channel water level and flow information.

 For irrigation channel flow measurement cross-sections, a measurement bridge is installed. To reduce costs, two parallel triangular tracks are laid on the upstream side of the measurement bridge, with one end of the tracks extending into the measurement house. The positions and number of measurement vertical lines are determined based on the width of the channel cross-section. When measurement is initiated, the measurement vehicle moves to the measurement point, measures water level and water depth (sediment thickness), and provides real-time feedback on measurement data and status. The flow measurement vehicle lowers the flow velocity meter to a fixed depth for single-point flow velocity measurement or layered flow velocity measurement. After measurement is complete, it moves to the next measurement point for measurement.

After all measurement points are completed, the flow measurement vehicle calculates the partial average flow velocity and partial area for each vertical line, calculates the partial flow rate, and sums the partial flow rates to obtain the total flow rate for the cross-section.

  

 

  That concludes the basic introduction to the mainstream products currently available on the market. Please forgive any inaccuracies and feel free to point them out. If there are any omissions, we welcome your input. Now let’s discuss selection criteria.

4. How do you choose the appropriate flow meter for practical applications?

 The editor has summarized two categories of selection issues that are of particular concern: 1: How to select a flow meter for measuring flow in channels/rivers of different widths? 2: How to select a flow meter for measuring flow in channels/rivers with different purposes?

◆ Select based on channel/river width from largest to smallest

  

 

 

  There are three main uses for channel/river flow measurement: 1. Metering: such as irrigation districts and water distribution scheduling, which require high accuracy. 2. Hydrological flow measurement: major hydrological bureaus focus on flow data within specific areas, which requires rigorous data accuracy. 3. Flood prevention and control: such as flash floods and urban flood drainage, which focus on relative changes in flow data.

 

◆ Select according to use

  

 

 

  Due to space limitations, we will not go into detail about maintenance issues for various types of flow sensors. If you are interested in any specific topics, please leave a message in the comments section, and we will prepare relevant content based on your feedback!

Welcome to leave a message for consultation

Our staff will contact you within 24 hours (on working days). If you need any other services, please feel free to call our service hotline:+86-592-6266612