Suspended Solids Sensor
Category:
keyword:
Water Level Sensor section
1. Equipment introduction:
The integrated online self-cleaning suspended solids sensor is designed and manufactured based on the principle of scattered light suspended solids measurement method. When a beam of light enters the water sample, the suspended matter in the water sample scatters the light. By measuring the intensity of the scattered light perpendicular to the incident light and comparing it with the internal calibration value, the suspended matter in the water sample is calculated and linearized to output the final value.
2. Application direction:
Suitable for various water environment monitoring scenarios. In municipal sewage treatment, the concentration of suspended solids in water can be monitored in real time to ensure that the treated water meets the discharge standards. In the field of industrial wastewater treatment, it can accurately measure the suspended solids content to ensure the quality of production water. In addition, it can also be used for monitoring surface water such as rivers and lakes, timely warning of water quality changes, and providing data support for environmental protection.
3. Advantages and features of equipment:
Measurement accuracy: using the principle of scattered light method, with a range of 0-3000mg/L and an accuracy of ± 5% F.S, it can accurately measure the concentration of suspended solids in water;
Self cleaning design: equipped with automatic cleaning function, adjustable cleaning interval and speed, effectively preventing dirt from adhering and reducing maintenance workload;
Convenient communication: Supports RS-485 (Modbus/RTU) output, strong compatibility, and easy access to various monitoring systems;
High protection level: IP68 protection level, able to work stably underwater for a long time and adapt to harsh environments;
Easy to operate: Provides detailed communication protocols and calibration methods, allowing users to easily read data and calibrate equipment.
Technical parameters
Category |
Details |
Measurement principle |
Scattering light method |
Measurement range |
0~3000mg/L |
Resolution |
0.1mg/L ±0.1℃ |
Measurement accuracy |
±5%F.S |
Calibration method |
Two-point calibration |
Temperature compensation |
Automatic temperature compensation (Pt1000) |
Output mode |
RS-485(Modbus/RTU) |
Working conditions |
0~50℃, <0.2MPa |
Storage temperature |
-5~65℃ |
Case material |
304 Stainless Steel and ABS |
Installation method |
Immersion installation, 3/4" NPT pipe thread |
Cable length |
Standard 10 meters, can be customized |
Supply voltage |
12~24VDC |
Protection level |
IP68 |
Related products