Vibration string osmometer (model: HC-SWY10)
Category:
keyword:
Water Level Sensor section
1. Equipment introduction:
Through continuous accumulation of production process technology, advanced mixed signal processing technology, and unique compensation methods, high-precision liquid level measurement products can achieve full range digital linear correction, full temperature range digital temperature error compensation, compensation parameters stored in non-volatile memory, and multiple safety protection mechanisms to avoid product failure due to calibration parameter loss; The circuit part is equipped with power monitoring and watchdog monitoring functions, and the mechanical part is a fully sealed stainless steel structure, greatly improving the reliability of the entire machine. Due to the use of low-power devices in all circuits, the overall power consumption of the machine is very low, with approximately 4mA at full speed operation. This feature is very useful in situations where battery power is required.
2. Application direction:
Widely used in freshwater drinking water treatment, wastewater and sewage treatment, seawater measurement, and surface water or groundwater monitoring in the hydrological and water conservancy industry.
3. Installation diagram:

4. Advantages and features of equipment:
♦ High stability liquid level measurement sensing element, with good long-term stability;
♦ High precision, up to 0.05% FS (linear, repetitive, hysteresis);
♦ Strong overload capacity, with an overload of 3-5 times the full range;
♦ Using mixed signal microprocessors and high-order fitting algorithms to achieve high-precision compensation;
♦ The RS485 standard MODBUS-RTU protocol can be used in DCS or PLC systems;
♦ Low power consumption characteristics, with a power consumption of about 4mA when operating at full speed, and outstanding advantages when powered by external batteries;
♦ The product is equipped with both reverse power protection and surge voltage protection;
♦ Optional unique air filter device to prevent condensation and blockage in the atmosphere compensation capillary tube.
Technical parameters
Main performance indicators
|
Range |
0~10, 20, 50, 100mH2O |
|
User-specified range, factory calibration |
|
|
Measurement accuracy |
0.2%F·S |
|
Resolution |
0.005% FS |
|
Long-term stability |
0.1%FS/year |
|
Overload capability |
5X FS |
Temperature characteristics
|
Zero temperature coefficient |
0.005%F·S/℃ |
|
Full scale temperature coefficient |
0.005% F·S/℃ |
|
Compensation temperature |
0~50℃ |
|
Operating temperature |
-20~85℃ |
|
Storage temperature |
-40~125℃ |
Electrical characteristics
|
Power supply voltage |
12VDC (9 ~30V) |
|
Communication interface protection |
(2KV) Surge Voltage |
|
Load capacity |
128 transmitter nodes |
|
Output method |
RS485 interface, MODBUS-RTU protocol |
|
insulation |
100MΩ@50V |
Mechanical characteristics
|
Sensor life |
10' full-scale pressure cycle |
|
Liquid material |
Alumina ceramic gold plating |
|
Sealing ring material |
Fluoroelastomer |
|
Housing material |
316L stainless steel (optional titanium alloy) |
|
Cable material |
Juanzhi |
|
weight |
About 300 grams |
Environmental characteristics
|
vibration |
20g 20~5000Hz |
|
Impact |
20g 11ms |
|
Protection level |
IP68 |
|
Explosion-proof level |
Exia II C T6 |
|
Air filter protection level |
IP67 |